Home>SAE standards list>SAE J1320:2019 pdf free

SAE J1320:2019 pdf free

SAE J1320:2019 pdf free.Marine Electrical Switches
With the switch mounted as recommended by the manufacturer, each terminal or pigtail shall be subjected to 10 Ib of axial tension for 1 h at room temperature. The tension loads shall then be removed. The switch shall then be hot and cold cycled 10 times with each cycle consisting of 30 min at room temperature, 30 min at – 35 °C (- 30°F), 30 min at room temperature, 30 min at 100 °C (212 °F), and then allowed to cool to room temperature. The switch shall be mechanically operated 10 times at each temperature extreme. The temperature cycled switch must then not have a voltage drop in excess of three times that measured in 5.1.Marine switches shall be constructed of corrosion resistant materials, shall be tested to ASTM B 117 for 100 h, and still have a satisfactory appearance.
A water tight switch is recommended for any application where the switch may become submerged. To be considered a water tight switch, the switch must pass the conditions in 5.3 and then be submerged 14 in below the surface of a 5% solution of salt water for 1 h. After removal from the solution, the external portion of the switch is to be washed with fresh water and dried. The switch must then pass the conditions in 5.2. Water tight switches complying with this recommended practice, except those covered in 6.4, are designated Type A.
A weatherproof switch is recommended for use in areas where the switch will be subjected to rain, spray, or splashing. To be considered weatherproof, when mounted in the manufacturer’s recommended manner, the switch shall be subjected to a 5% salt water spray test where the switch shall be mounted in the spray (reference ASTM D 1735, steps 7 and 8) for 96 h. At the completion of the test, the external portion of the switch shall be washed with fresh water and dried.
There shall not be more than 10 mA flowing when tested in accordance with 5.2.Weatherproof switches complying with this recommended practice, except those covered in 6.3, are designated Type B.SAE J1320 pdf free download.

Related Standards

Categories